Pertemuan 5P_Pompa panas sumber air MDS50D_kompresor Copeland 380V pemanas air panas rumah hemat daya suhu tinggi
Spesifikasi Teknologi
Pompa panas sumber air
| MODEL | Satuan | MDS15D | |
| Kapasitas pemanasan terukur | KW | 5 | |
| Pasokan air panas | L/j | 100 | |
| Daya masukan pemanasan rata-rata | KW | 1.2 | |
| Arus masukan pemanasan terukur | A | 6 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4 | ||
| Daya | V/Hz | 220V/50 | |
| Kebisingan | Db(a) | 50 | |
| Dimensi | P*L*T | mm | 657×557×765 |
| Ukuran pengepakan | P*L*T | mm | 737×637×915 |
| Berat unit | KG | 75 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Panasonic | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 25 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 2000L/j | |
| Penurunan tekanan air | Kpa | 30 | |
| Ukuran pipa | DN | 25 | |
| Pemanasan rumah maks | M2 | 40 | |
| MODEL | Satuan | MDS20D | |
| Kapasitas pemanasan terukur | KW | 7 | |
| Pasokan air panas | L/j | 150 | |
| Daya masukan pemanasan rata-rata | KW | 1.7 | |
| Arus masukan pemanasan terukur | A | 9 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4 | ||
| Daya | V/Hz | 220V/50 | |
| Kebisingan | Db(a) | 50 | |
| Dimensi | P*L*T | mm | 657×557×765 |
| Ukuran pengepakan | P*L*T | mm | 737×637×915 |
| Berat unit | KG | 75 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Panasonic | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 25 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 2000L/j | |
| Penurunan tekanan air | Kpa | 30 | |
| Ukuran pipa | DN | 25 | |
| Pemanasan rumah maks | M2 | 55 | |
| MODEL | Satuan | MDS30D | |
| Kapasitas pemanasan terukur | KW | 12 | |
| Pasokan air panas | L/j | 260 | |
| Daya masukan pemanasan rata-rata | KW | 2.89 | |
| Arus masukan pemanasan terukur | A | 13/6 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4 | ||
| Daya | V/Hz | 220V/380V/50 | |
| Kebisingan | Db(a) | 50 | |
| Dimensi | P*L*T | mm | 657×557×765 |
| Ukuran pengepakan | P*L*T | mm | 737×637×915 |
| Berat unit | KG | 108 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 25 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 3300L/j | |
| Penurunan tekanan air | Kpa | 35 | |
| Ukuran pipa | DN | 25 | |
| Pemanasan rumah maks | M2 | 100 | |
| MODEL | Satuan | MDS40D | |
| Kapasitas pemanasan terukur | KW | 16 | |
| Pasokan air panas | L/j | 380 | |
| Daya masukan pemanasan rata-rata | KW | 4 | |
| Arus masukan pemanasan terukur | A | 9 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4.2 | ||
| Daya | V/Hz | 380V/50 | |
| Kebisingan | Db(a) | 50 | |
| Dimensi | P*L*T | mm | 657×557×765 |
| Ukuran pengepakan | P*L*T | mm | 737×637×915 |
| Berat unit | KG | 145 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 32 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 4000L/j | |
| Penurunan tekanan air | Kpa | 40 | |
| Ukuran pipa | DN | 25 | |
| Pemanasan rumah maks | M2 | 125 | |
| MODEL | Satuan | MDS50D | |
| Kapasitas pemanasan terukur | KW | 19 | |
| Pasokan air panas | L/j | 400 | |
| Daya masukan pemanasan rata-rata | KW | 4.4 | |
| Arus masukan pemanasan terukur | A | 9 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4.2 | ||
| Daya | V/Hz | 380V/50 | |
| Kebisingan | Db(a) | 50 | |
| Dimensi | P*L*T | mm | 657×557×765 |
| Ukuran pengepakan | P*L*T | mm | 737×637×915 |
| Berat unit | KG | 145 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 32 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 5000L/j | |
| Penurunan tekanan air | Kpa | 40 | |
| Ukuran pipa | DN | 25 | |
| Pemanasan rumah maks | M2 | 150 | |
| MODEL | Satuan | MDS60D | |
| Kapasitas pemanasan terukur | KW | 25 | |
| Pasokan air panas | L/j | 520 | |
| Daya masukan pemanasan rata-rata | KW | 6 | |
| Arus masukan pemanasan terukur | A | 12 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4.5 | ||
| Daya | V/Hz | 380V/50 | |
| Kebisingan | Db(a) | 50 | |
| Dimensi | P*L*T | mm | 657×557×765 |
| Ukuran pengepakan | P*L*T | mm | 737×637×915 |
| Berat unit | KG | 158 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 32 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 6000L/j | |
| Penurunan tekanan air | Kpa | 45 | |
| Ukuran pipa | DN | 25 | |
| Pemanasan rumah maks | M2 | 175 | |
| Model | Satuan | MDS100D | |
| Kapasitas pemanasan terukur | KW | 38 | |
| Pasokan air panas | L/j | 800 | |
| Daya masukan pemanasan rata-rata | KW | 8.8 | |
| Arus masukan pemanasan terukur | A | 18 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4.6 | ||
| Daya | V/Hz | 380V/50 | |
| Kebisingan | Db(a) | 55 | |
| Dimensi | P*L*T | mm | 1050*810*760 |
| Ukuran pengepakan | P*L*T | mm | 1140*900*910 |
| Berat unit | KG | 290 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 32 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 10000L/j | |
| Penurunan tekanan air | Kpa | 50 | |
| Ukuran pipa | DN | 32 | |
| Pemanasan rumah maks | M2 | 300 | |
| Model | Satuan | MDS150D | |
| Kapasitas pemanasan terukur | KW | 42 | |
| Pasokan air panas | L/j | 1200 | |
| Daya masukan pemanasan rata-rata | KW | 11 | |
| Arus masukan pemanasan terukur | A | 21 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4.6 | ||
| Daya | V/Hz | 380V/50 | |
| Kebisingan | Db(a) | 55 | |
| Dimensi | P*L*T | mm | 1050*810*760 |
| Ukuran pengepakan | P*L*T | mm | 1140*900*910 |
| Berat unit | KG | 300 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 32 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | L/J | 15000L/j | |
| Penurunan tekanan air | Kpa | 50 | |
| Ukuran pipa | DN | 32 | |
| Pemanasan rumah maks | M2 | 350 | |
| MODEL | Satuan | MDS200D | |
| Kapasitas pemanasan terukur | KW | 74 | |
| Pasokan air panas | L/j | 1590 | |
| Daya masukan pemanasan rata-rata | KW | 17.6 | |
| Arus masukan pemanasan terukur | A | 36 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4.6 | ||
| Daya | V/Hz | 380V/50 | |
| Kebisingan | Db(a) | 58 | |
| Dimensi | P*L*T | mm | 1260×850×860 |
| Ukuran pengepakan | P*L*T | mm | 1350×910×1020 |
| Berat unit | KG | 630 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas pelat | |
| Ukuran pipa | DN | 63 | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | M3/J | 20000L/j | |
| Penurunan tekanan air | Kpa | 55 | |
| Ukuran pipa | DN | 50 | |
| Pemanasan rumah maks | M2 | 600 | |
| MODEL | Satuan | MDS300D | |
| Kapasitas pemanasan terukur | KW | 100 | |
| Pasokan air panas | L/j | 2400 | |
| Daya masukan pemanasan rata-rata | KW | 25 | |
| Arus masukan pemanasan terukur | A | 45 | |
| Suhu air keluar maks | ℃ | 80 | |
| COP | 4.6 | ||
| Daya | V/Hz | 380V/50 | |
| Kebisingan | Db(a) | 55 | |
| Dimensi | P*L*T | mm | 1260×850×860 |
| Ukuran pengepakan | P*L*T | mm | 1350×910×1020 |
| Berat unit | KG | 660 | |
| Refrigeran | R134A | ||
| Rentang suhu udara kerja | ℃ | (-40℃)—45℃ | |
| kompresor | Tipe | Copeland | |
| penukar panas sumber air | Tipe | Pertukaran panas tabung | |
| Pertukaran panas sisi air panas | Tipe | Penukar panas koil | |
| Aliran air | M3/J | 30000L/j | |
| Penurunan tekanan air | Kpa | 60 | |
| Ukuran pipa | DN | 50 | |
| Pemanasan rumah maks | M2 | 730 | |
Deskripsi Produk
Ruang lingkup yang berlaku: Peternakan waduk di dekat sungai dan danau, hotel, sekolah, rumah sakit, asrama staf pabrik dan tempat lainnya.
1. Sistem pompa panas sumber air adalah sistem pendingin yang sangat efisien dan hemat energi yang memanfaatkan sumber daya panas bumi dangkal bawah tanah (juga dikenal sebagai energi tanah, termasuk air tanah, tanah, atau air permukaan). Sumber daya panas bumi yang stabil sepanjang tahun untuk memenuhi permintaan panas dan dingin, itu adalah pilihan terbaik untuk wilayah alpine untuk mendapatkan air panas dan pemanasan.
2. Mesin mengadopsi kompresor merek internasional, dengan teknologi paten penukar panas yang efisien, pendinginan dan pemanasan lebih bertenaga, efisiensi tinggi, teknologi kontrol cerdas komputer mikro otomatis, mengatur fungsi perlindungan ganda.
Layanan Kami
2. Sistem layanan Pengendalian Cerdas akan menghindari jarak jauh dari masalah purna jual. Di mana pun Anda berada, teknisi kami dapat mengontrol peralatan Anda, ketika beberapa pertanyaan muncul pada peralatan. Beri tahu kami nomor berapa yang akan ditampilkan di layar, maka teknisi akan menyelesaikan masalahnya.
3. Kami menerima OEM, ODM dan kustomisasi.
4.24*7 layanan purna jual. Anda akan mendapatkan layanan yang memuaskan.
5. Kami memiliki pengalaman produksi dan penjualan Lebih dari 17 tahun; Tim penjualan profesional.
6. Waktu pengiriman cepat: pesanan kecil: 3-5 hari, pesanan massal: 15-25 hari.
Pompa sistem air ke air memompa panas melalui penggunaan sistem pendingin sederhana, ia memompa panas dari bumi yang hangat di musim dingin dan memindahkannya ke rumah atau bisnis Anda. Di musim panas, prosesnya dibalik. Karena biaya untuk memindahkan panas jauh lebih sedikit daripada membuatnya, jauh lebih sedikit energi yang dikonsumsi.
Untuk sistem loop tertutup, air atau larutan antibeku diedarkan melalui pipa plastik yang terkubur di bawah permukaan bumi. Selama musim dingin, cairan mengumpulkan panas dari bumi dan membawanya melalui sistem dan menempatkannya di tanah.
Sistem terbuka beroperasi pada prinsip yang sama dengan sistem loop tertutup dan dapat dipasang di mana pasokan air yang memadai tersedia dan pembuangan terbuka layak.
Loop dapat dipasang dengan tiga cara: horizontal, vertikal atau di kolam atau danau. Jenis yang dipilih tergantung pada area lahan yang tersedia dan jenis tanah dan batuan di lokasi pemasangan.
Deskripsi pabrik pompa panas sumber air ke air monoblock evi:
* Desain produk dan produksi pompa panas dengan standar Eropa EN14511, disetujui oleh ECM dengan efisiensi tingginya. Pabrik diaudit oleh Biro Veritas.
* Memberikan kapasitas yang lebih tinggi pada suhu penguapan rendah sehingga lebih baik menanggapi persyaratan pemanasan berkat kompresor EVI
* Ini juga menghasilkan lebih sedikit pemanasan tambahan untuk menutupi permintaan pemanasan penuh pada hari-hari terdingin.
* Rentang suhu sekitar yang dapat digunakan - 25℃ hingga 35℃.
* Motor kipas hemat energi dua kecepatan. Kecepatan kipas bervariasi sehingga hanya jumlah udara yang dibutuhkan yang digunakan. Bilah dirancang khusus untuk memindahkan udara sebanyak mungkin pada tingkat kebisingan terendah.
* Timer ON/OFF.
* Kurva panas yang bervariasi. Suhu air terkontrol bervariasi sesuai dengan suhu sekitar
* Sebagian besar komponen disegel dengan baik untuk mempertahankan panas dan mencegah tetesan
1. Kompresor gulir Copeland EVI R407C.
2. Dirancang untuk pemanas sentral untuk rumah di daerah dingin termasuk Eropa Utara dan Eropa Timur.
3. Dapat bekerja secara stabil pada suhu sekitar -25DegC dan COP pada suhu sekitar -15DegC hingga 2,5.
4. Dapat bekerja dengan pemanas tambahan.
5. Menggunakan katup ekspansi elektronik, mencapai penekanan yang akurat, stabil, dan efisiensi tinggi.
6. Desain terpisah, tidak ada sistem air di luar, tidak ada pembekuan dan kerusakan pada sistem air. Koneksi cepat pipa refrigeran opsional tersedia, untuk mengurangi biaya pemasangan.
7. Desain kebisingan rendah untuk unit luar ruangan. Kompresor berada di pelat mengambang untuk mengurangi getaran pada sebagian besar. Insulasi kebisingan di dalam kabinet. Kipasnya sangat sunyi.
8. Sambungan refrigeran dirancang untuk memungkinkan menyembunyikan semua pipa, kabel ke dalam tanah untuk memastikan pemasangan yang tampak bagus.
Hubungi kami kapan saja