1.5P meeting_MDS15D pompa di calore a sorgente d'acqua_220V compressore Copeland per riscaldamento acqua calda domestico a risparmio energetico ad alta temperatura
Specifiche Tecniche
Pompa di calore a sorgente d'acqua
| MODEL | Unit | MDS15D | |
| Rated heating capacity | KW | 5 | |
| Hot water supply | L/h | 100 | |
| Average heating input power | KW | 1.2 | |
| Rated heating input current | A | 6 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 657×557×765 |
| Packing size | W*D*H | mm | 737×637×915 |
| Unit weight | KG | 75 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Panasonic | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 25 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 2000L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 25 | |
| Max house heating | M2 | 40 | |
| MODEL | Unit | MDS20D | |
| Rated heating capacity | KW | 7 | |
| Hot water supply | L/h | 150 | |
| Average heating input power | KW | 1.7 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4 | ||
| Power | V/Hz | 220V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 657×557×765 |
| Packing size | W*D*H | mm | 737×637×915 |
| Unit weight | KG | 75 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Panasonic | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 25 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 2000L/h | |
| Water pressure down | Kpa | 30 | |
| Pipe size | DN | 25 | |
| Max house heating | M2 | 55 | |
| MODEL | Unit | MDS30D | |
| Rated heating capacity | KW | 12 | |
| Hot water supply | L/h | 260 | |
| Average heating input power | KW | 2.89 | |
| Rated heating input current | A | 13/6 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4 | ||
| Power | V/Hz | 220V/380V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 657×557×765 |
| Packing size | W*D*H | mm | 737×637×915 |
| Unit weight | KG | 108 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 25 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 3300L/h | |
| Water pressure down | Kpa | 35 | |
| Pipe size | DN | 25 | |
| Max house heating | M2 | 100 | |
| MODEL | Unit | MDS40D | |
| Rated heating capacity | KW | 16 | |
| Hot water supply | L/h | 380 | |
| Average heating input power | KW | 4 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 657×557×765 |
| Packing size | W*D*H | mm | 737×637×915 |
| Unit weight | KG | 145 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 32 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 4000L/h | |
| Water pressure down | Kpa | 40 | |
| Pipe size | DN | 25 | |
| Max house heating | M2 | 125 | |
| MODEL | Unit | MDS50D | |
| Rated heating capacity | KW | 19 | |
| Hot water supply | L/h | 400 | |
| Average heating input power | KW | 4.4 | |
| Rated heating input current | A | 9 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4.2 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 657×557×765 |
| Packing size | W*D*H | mm | 737×637×915 |
| Unit weight | KG | 145 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 32 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 5000L/h | |
| Water pressure down | Kpa | 40 | |
| Pipe size | DN | 25 | |
| Max house heating | M2 | 150 | |
| MODEL | Unit | MDS60D | |
| Rated heating capacity | KW | 25 | |
| Hot water supply | L/h | 520 | |
| Average heating input power | KW | 6 | |
| Rated heating input current | A | 12 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4.5 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 50 | |
| Dimension | W*D*H | mm | 657×557×765 |
| Packing size | W*D*H | mm | 737×637×915 |
| Unit weight | KG | 158 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 32 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 6000L/h | |
| Water pressure down | Kpa | 45 | |
| Pipe size | DN | 25 | |
| Max house heating | M2 | 175 | |
| Modello | Unit | MDS100D | |
| Rated heating capacity | KW | 38 | |
| Hot water supply | L/h | 800 | |
| Average heating input power | KW | 8.8 | |
| Rated heating input current | A | 18 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4.6 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 55 | |
| Dimension | W*D*H | mm | 1050*810*760 |
| Packing size | W*D*H | mm | 1140*900*910 |
| Unit weight | KG | 290 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 32 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 10000L/h | |
| Water pressure down | Kpa | 50 | |
| Pipe size | DN | 32 | |
| Max house heating | M2 | 300 | |
| Modello | Unit | MDS150D | |
| Rated heating capacity | KW | 42 | |
| Hot water supply | L/h | 1200 | |
| Average heating input power | KW | 11 | |
| Rated heating input current | A | 21 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4.6 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 55 | |
| Dimension | W*D*H | mm | 1050*810*760 |
| Packing size | W*D*H | mm | 1140*900*910 |
| Unit weight | KG | 300 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 32 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | L/H | 15000L/h | |
| Water pressure down | Kpa | 50 | |
| Pipe size | DN | 32 | |
| Max house heating | M2 | 350 | |
| MODEL | Unit | MDS200D | |
| Rated heating capacity | KW | 74 | |
| Hot water supply | L/h | 1590 | |
| Average heating input power | KW | 17.6 | |
| Rated heating input current | A | 36 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4.6 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 58 | |
| Dimension | W*D*H | mm | 1260×850×860 |
| Packing size | W*D*H | mm | 1350×910×1020 |
| Unit weight | KG | 630 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Plate heat exchange | |
| Pipe size | DN | 63 | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | M3/H | 20000L/h | |
| Water pressure down | Kpa | 55 | |
| Pipe size | DN | 50 | |
| Max house heating | M2 | 600 | |
| MODEL | Unit | MDS300D | |
| Rated heating capacity | KW | 100 | |
| Hot water supply | L/h | 2400 | |
| Average heating input power | KW | 25 | |
| Rated heating input current | A | 45 | |
| Max outlet water temp | ℃ | 80 | |
| COP | 4.6 | ||
| Power | V/Hz | 380V/50 | |
| Noise | Db(a) | 55 | |
| Dimension | W*D*H | mm | 1260×850×860 |
| Packing size | W*D*H | mm | 1350×910×1020 |
| Unit weight | KG | 660 | |
| Refrigerant | R134A | ||
| Working air temp range | ℃ | (-40℃)—45℃ | |
| compressor | Type | Copeland | |
| water source heat exchanger | Type | Tube heat exchange | |
| Hot water side heat exchange | Type | Coil heat exchanger | |
| Water flow | M3/H | 30000L/h | |
| Water pressure down | Kpa | 60 | |
| Pipe size | DN | 50 | |
| Max house heating | M2 | 730 | |
Descrizione del prodotto
Ambito di applicazione: le fattorie di bacini idrici vicino a fiumi e laghi, hotel, scuole, ospedali, alloggi per il personale di fabbrica e altri luoghi.
1. Il sistema di pompe di calore a sorgente d'acqua è un sistema di refrigerazione ad alta efficienza e a risparmio energetico che utilizza risorse geotermiche sotterranee poco profonde (note anche come energia del suolo, tra cui acque sotterranee, suolo o acque superficiali). Risorse geotermiche stabili durante tutto l'anno per soddisfare la domanda di caldo e freddo, è la scelta migliore per la regione alpina per ottenere acqua calda e riscaldamento.
2. La macchina adotta un compressore di marca internazionale, con scambiatore di calore efficiente con tecnologia brevettata, refrigerazione e riscaldamento più potenti, alta efficienza, tecnologia di controllo intelligente a microcomputer automatico, imposta la funzione di protezione multipla.
I nostri servizi
2. Il sistema di servizio di controllo intelligente eviterà la lunga distanza del problema post-vendita. Ovunque tu sia, il nostro tecnico può controllare la tua attrezzatura, quando si verificano alcune domande sull'attrezzatura. Basta dirci quale numero verrà visualizzato sullo schermo, quindi l'ingegnere risolverà il problema.
3. Accettiamo OEM, ODM e personalizzazione.
4.24*7 servizio post-vendita. Riceverai un servizio soddisfacente.
5. Abbiamo più di 17 anni di esperienza nella produzione e nelle vendite; Team di vendita professionale.
6. Tempi di consegna rapidi: piccolo ordine: 3-5 giorni, ordine all'ingrosso: 15-25 giorni.
Le pompe del sistema acqua-acqua riscaldano attraverso l'uso di un semplice sistema di refrigerazione, pompano il calore dalla terra calda in inverno e lo spostano nella tua casa o attività commerciale. In estate, il processo viene invertito. Poiché costa molto meno spostare il calore che produrlo, si consuma molta meno energia.
Per il sistema a circuito chiuso, l'acqua o una soluzione antigelo viene fatta circolare attraverso tubi di plastica interrati sotto la superficie terrestre. Durante l'inverno il fluido raccoglie il calore dalla terra e lo trasporta attraverso il sistema e lo posiziona nel terreno.
I sistemi aperti funzionano sullo stesso principio dei sistemi a circuito chiuso e possono essere installati dove è disponibile un'adeguata fornitura di acqua adatta e gli scarichi aperti sono fattibili.
I circuiti possono essere installati in tre modi: orizzontalmente, verticalmente o in uno stagno o lago. Il tipo scelto dipende dall'area di terreno disponibile e dal tipo di suolo e roccia nel sito di installazione.
Descrizione della fabbrica della pompa di calore a sorgente d'acqua monoblocco evi:
* I prodotti progettano e producono pompe di calore secondo lo standard europeo EN14511, approvato da ECM con la sua alta efficienza. Fabbrica controllata da Bureau Veritas.
* Fornisce una capacità maggiore a bassa temperatura di evaporazione, rispondendo così meglio alle esigenze di riscaldamento grazie al compressore EVI
* Ciò si traduce anche in un minore riscaldamento supplementare per coprire la piena richiesta di riscaldamento nei giorni più freddi.
* Intervallo di temperatura ambiente di lavoro da -25℃ a 35℃.
* Motori dei ventilatori a risparmio energetico a due velocità. La velocità della ventola varia, quindi viene utilizzata solo la quantità di aria richiesta. Le pale sono appositamente progettate per spostare la maggior quantità di aria possibile al livello di rumore più basso.
* Timer ON/OFF.
* Curva di calore variabile. La temperatura dell'acqua controllata varia in base alla temperatura ambiente
* La maggior parte dei componenti sono ben sigillati per trattenere il calore e prevenire il gocciolamento
1. Compressore Copeland EVI scroll R407C.
2. Progettato per il riscaldamento centralizzato per case in aree fredde, tra cui Europa settentrionale ed Europa orientale.
3. Può funzionare stabilmente a -25°C ambiente e il COP a -15°C ambiente è fino a 2,5.
4. Può funzionare con un riscaldatore ausiliario.
5. Utilizzo della valvola di espansione elettronica, ottenendo un'accelerazione precisa, stabile e ad alta efficienza.
6. Design diviso, nessun sistema idrico all'esterno, nessun congelamento e danni al sistema idrico. È disponibile un collegamento rapido del tubo del refrigerante opzionale, per ridurre i costi di installazione.
7. Design a basso rumore per l'unità esterna. Il compressore è su una piastra flottante per ridurre al massimo le vibrazioni. Isolamento acustico all'interno dell'armadio. La ventola è estremamente silenziosa.
8. I collegamenti del refrigerante sono progettati per consentire di nascondere tutti i tubi, i fili nel terreno per garantire una buona installazione.
Contattaci in qualsiasi momento